Creating clean air pathways through targeted low-level extraction

Genesis® offers a range of modular upgrades solving many ventilation challenges.
Solving ventilation compliance challenges for hospital estates teams
NHS hospitals face a growing ventilation compliance backlog. Ageing air handling units, spaces repurposed for changing clinical use, and the practical limitations of ceiling-based extract systems all create risk — clinical, legal and financial. GENESIS® low-level extract from Air Sentry is designed specifically to address these challenges, offering a cost-effective, rapidly deployable and low-disruption solution aligned with HTM 03-01. Suitable for both first-fix installation and retrofit applications, GENESIS® can integrate with existing HVAC infrastructure, improving ventilation effectiveness without the significant capital expenditure, disruption and lengthy lead times associated with major Air Handling Unit (AHU) upgrades or replacement.
How Genesis works
Available in mid-wall or corner configurations, Genesis ensures that vector airflow across a room delivers the dilution demanded within healthcare spaces. The corner version offers further upgrade possibilities including optional fresh air supply, recirculated HEPA filtered air, and pressure differential capability when combined with Aristotle® IAQ monitoring.
Genesis can be installed as first fix or retrofit and offers standard HVAC duct connection, facilitating straightforward integration with existing systems. It is also available with anti-ligature grilles, making it suitable for mental health and secure environments.
By providing low-level extract, Genesis assists in achieving HTM03.01 compliance and enhances patient and staff safety across a wide range of clinical settings — from general wards and respiratory assessment units to infectious disease areas and maternity environments.

Recognised for Innovation
Genesis® has been shortlisted for Product Innovation of the Year at the IHEEM Healthcare Estates Awards 2026 — one of the most prestigious recognition programmes in the UK healthcare estates and facilities management sector.
The shortlisting, under the entry title “Genesis, A New Beginning”, reflects the product’s distinctive approach to a longstanding clinical estates challenge: delivering HTM03.01-compliant ventilation performance in environments where traditional ceiling-based systems fall short, without the disruption and cost of major capital works.
Why low-level extract matters
The consequences of inadequate ventilation in clinical environments can be severe. In October 2026, Mid and South Essex NHS Foundation Trust settled claims from 121 staff — including 85 midwives — totalling £735,000, following prolonged exposure to dangerous levels of nitrous oxide (N₂O) at Basildon Hospital’s maternityunit. Some staff were found to have been exposed to levels up to 30 times the legal workplace exposure limit. The Royal College of Midwives described it as the largest group legal action ever brought by midwives in the UK.
Effective removal of nitrous oxide (N₂O) depends not only on ventilation air change rates, but also on how air moves through the occupied space. Conventional ceiling-level supply and extraction arrangements can result in air short-circuiting between grilles, potentially reducing the effectiveness of contaminant removal at patient and staff level.
HTM 03-01 and NHS England’s guidance on minimising occupational exposure to nitrous oxide specifically recommend high-level fresh air supply combined with low-level extraction to establish clean air pathways through the occupied zone. GENESIS® is designed to support this recommended ventilation principle, providing targeted low-level extraction that helps draw contaminated air away from occupants and towards the extract point.
When combined with Aristotle® intelligent air quality monitoring, GENESIS® can form part of an integrated ventilation solution, providing real-time monitoring of N₂O, CO₂, particulates, temperature and humidity, with automated fan control to increase extraction in response to rising contaminant levels.
For NHS trusts managing ventilation compliance backlogs, the Basildon case is a clear illustration of the legal, financial and reputational exposure that inadequate monitoring and remediation carries. Low-level extract, paired with intelligent IAQ monitoring, is not merely a technical upgrade — it is a risk management imperative.
Talk to us
To discuss how Genesis can support your ventilation compliance strategy, contact Air Sentry at webrequest@airsentry.co.uk or call 01249 721422. 24-hour support is available on 01666 818087.